Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microsc ; 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38115688

RESUMO

Reliable and consistent preparation of atom probe tomography (APT) specimens from aqueous and hydrated biological specimens remains a significant challenge. One particularly difficult process step is the use of a focused ion beam (FIB) instrument for preparing the required needle-shaped specimen, typically involving a 'lift-out' procedure of a small sample of material. Here, two alternative substrate designs are introduced that enable using FIB only for sharpening, along with example APT datasets. The first design is a laser-cut FIB-style half-grid close to those used for transmission electron microscopy (TEM) that can be used in a grid holder compatible with APT pucks. The second design is a larger, standalone self-supporting substrate called a 'crown', with several specimen positions, which self-aligns in APT pucks, prepared by electrical discharge machining (EDM). Both designs are made nanoporous, to provide strength to the liquid-substrate interface, using chemical and vacuum dealloying. Alpha brass, a simple, widely available, lower-cost alternative to previously proposed substrates, was selected for this work. The resulting designs and APT data are presented and suggestions are provided to help drive wider community adoption.

2.
Sci Adv ; 6(49)2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33277259

RESUMO

Transmission electron microscopy went through a revolution enabling routine cryo-imaging of biological and (bio)chemical systems, in liquid form. Yet, these approaches typically lack advanced analytical capabilities. Here, we used atom probe tomography to analyze frozen liquids in three dimensions with subnanometer resolution. We introduce a specimen preparation strategy using nanoporous gold. We report data on 2- to 3-µm-thick layers of ice formed from both high-purity deuterated water and a solution of 50 mM NaCl in high-purity deuterated water. The analysis of the gold-ice interface reveals a substantial increase in the solute concentrations across the interface. We explore a range of experimental parameters to show that atom probe analyses of bulk aqueous specimens come with their own challenges and discuss physical processes that produce the observed phenomena. Our study demonstrates the viability of using frozen water as a carrier for near-atomic-scale analysis of objects in solution by atom probe tomography.

3.
Ultramicroscopy ; 111(6): 738-42, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21215521

RESUMO

A model Al-3 Cu-(0.05 Sn) (wt%) alloy containing a bimodal distribution of relatively shear-resistant θ' precipitates and shearable GP zones is considered in this study. It has recently been shown that the addition of the GP zones to such microstructures can lead to significant increases in strength without a decrease in the uniform elongation. In this study, atom probe tomography (APT) has been used to quantitatively characterise the evolution of the GP zones and the solute distribution in the bimodal microstructure as a function of applied plastic strain. Recent nuclear magnetic resonance (NMR) analysis has clearly shown strain-induced dissolution of the GP zones, which is supported by the current APT data with additional spatial information. There is significant repartitioning of Cu from the GP zones into the solid solution during deformation. A new approach for cluster finding in APT data has been used to quantitatively characterise the evolution of the sizes and shapes of the Cu containing features in the solid solution solute as a function of applied strain.

4.
Microsc Res Tech ; 74(9): 799-803, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23939666

RESUMO

A limiting characteristic of the atom-probe technique is the nondetection of ions and this embodies a significant "missing information" problem in investigations of atomic clustering phenomena causing difficulty in the interpretation of any atom-probe experiment. It is shown that the measurable cluster-size distribution can be modeled by a mixed binomial distribution. A deconvolution method based upon expectation-maximization (EM) algorithm is presented to obtain the original physical distribution from an efficiency-degraded distribution, thereby providing means to calculate accurate cluster number densities from atom probe results. The accuracy of this restoration was predominantly dependent upon the detector efficiency and was proved to be highly accurate in the case of conventional atom-probe detector efficiencies (ε = 57%). Such considerations and measures are absolutely necessary when the number density of clusters and small precipitates is in any way regarded as important. We conclude that limitations in detector efficiency are more limiting for cluster-finding analyses via atom-probe techniques than spatial resolution issues, and therefore the current endeavors for improving detector technologies are well found.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...